British telecom specification CW1308 covers a range of internal cables which are used for interconnections between private telephone networks. These cables are also suitable for use within intercommunications systems, for alarm indication, signalling and control circuits and many other low voltage and current applications.
20 Pair + Earth CW1308 LSZH Internal Voice Cable
Application
The cable is designed to handle low frequency signals for short-range applications and is intended to be terminated in Insulation Displacement Connectors (IDC), but may be soldered or wrapped.
Construction
There are three modes of construction; Layer for general use, including two cables for installation in customer’s premises where a good appearance is required. Unit, of 20 pairs, including a 1.38mm diameter insulated earth conductor, for use with customer distribution schemes. Unit, of 16 pairs, for use with the binary number system. Unit, of 30 pairs, for use with Pulse Code Modulation (PCM) systems.
Product Description
Plain annealed solid copper wire, PVC insulated twisted pair or triple, LSZH sheath. An optional collective screen of aluminium coated polyester is available on request.